Access control kit designed to support two doors in the ST version of RACS 5 v2 system.
The kit includes a metal enclosure with a power supply, a networked access controller, and an I/O expander. The set supports two read-in/read-out doors using RS485 readers (MCT series readers or OSR readers equipped with OSDP protocol), RACS CLK / DTA (PRT series readers), or readers with Wiegand interface.
Each door is supported by an independent set of power outputs consisting of a 0.2 A output to power the readers and a 1.0 A output to power the lock and other door elements. The battery charging current can be set to 0.3 A, 0.6 A, or 0.9 A. The kit provides a complete supply of both controlled doors.
MC16-PAC-ST-2-KIT
Access control kit for 2 doors; ME-40 metal enclosure; MC16-PAC-ST-2 networked access controller; MCX2D I/O expander; PS2D power supply
pdf MC16-PAC-N-KIT Declaration of Conformity EC
pdf MC16 Declaration of Conformity EC
pdf MC16-PAC Declaration NO-04-A004-6:2016
pdf MC16 Declaration PN-EN50133
pdf MC16-PAC Declaration PN-EN60839 - grade II
pdf MC16-PAC Declaration PN-EN60839 - grade III
archive MC16 Firmware v1.1.1.208
archive MC16 Firmware v1.7.4.647
Note! Updating the firmware to version 1.7.4 requires a new controller license file. In version 1.7.4.647, support for alarm functions in the controller's Alarm Zone has been removed!