The MC16-PAC-EX is multi-door physical access and building automation controller dedicated to the EX version of the RACS 5 v2 system.
Depending on the version, it allows to control up to 16 read-in/out doors. MC16 can register events for Time & Attendance and can be integrated with intruder alarm systems. The integration enables a presentation of alarm zone status on terminal LEDs and to change zone status straight from a terminal. MC16 offers advanced and efficient methods for the management of users and their authorizations in the system. Controllers are configured in parallel and their total number does not affect the total configuration time which usually is below 1 minute.
Controllers are managed from VISO EX client-server Windows application operating with a centralized Microsoft SQL Server database. The system can be managed from multiple workstations by operators with various system rights. RACS 5 offers a software integration server and enables among others access to events and management of users.
Communication between the PC and controller is fully encrypted using the AES128-CBC method and can be conducted either in LAN or WAN.
Parameter | MC16-PAC-EX Versions | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | |
access doors | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
access points | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 |
access terminals | 4 | 8 | 12 | 16 | 20 | 24 | 28 | 32 | 36 | 40 | 44 | 48 | 52 | 56 | 60 | 64 |
access zones | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 |
alarm zones | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 |
power supplies | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 |
automation nodes | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 |
local commands | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 |
inputs | 8 | 12 | 18 | 24 | 30 | 36 | 42 | 48 | 54 | 60 | 66 | 72 | 78 | 84 | 90 | 96 |
outputs | 8 | 8 | 12 | 16 | 20 | 24 | 28 | 32 | 36 | 40 | 44 | 48 | 52 | 56 | 60 | 64 |
function keys | 8 | 16 | 24 | 32 | 40 | 48 | 56 | 64 | 72 | 80 | 88 | 96 | 104 | 112 | 120 | 128 |
access credentials | 12 000 | |||||||||||||||
access doors per access point |
1 |
MC16-PAC-EX-1
Access controller board; 1-door license
MC16-PAC-EX-2
Access controller board; 2-door license
MC16-PAC-EX-3
Access controller board; 3-door license
MC16-PAC-EX-4
Access controller board; 4-door license
MC16-PAC-EX-N
Access controller board; N-door license (N=1-16)
MC16-PAC-EX-LIC-1
1-door license extension for MC16-PAC-EX access controller
MC16-UPG-STtoEX-LIC-1
1-door license to upgrade the controller from MC16-PAC-ST to MC16-PAC-EX
pdf
MC16 Installation Manual
The manual refers to controllers with firmware v1.7.4 and higher
pdf
MC16 Operating Manual
The manual refers to controllers with firmware v1.7.4 and higher
pdf MC16 Declaration of Conformity EC
pdf MC16-PAC Declaration NO-04-A004-6:2016
pdf MC16 Declaration PN-EN50133
pdf MC16-PAC Declaration PN-EN60839 - grade II
pdf MC16-PAC Declaration PN-EN60839 - grade III
archive MC16 Firmware v1.1.1.208
archive
MC16 Firmware v1.7.4.647
Note! Updating the firmware to version 1.7.4 requires a new controller license file. In version 1.7.4.647, support for alarm functions in the controller's Alarm Zone has been removed!
Copyright © 2008-2023 Roger All rights reserved