Description:
I have SL2000 series code lock and I would like to change codes and program it properly.
Solution:
In order to configure the electronic keypad lock the EEPROM reset procedure should be carried out first. The EEPROM reset procedure restores factory defaults for codes as well as other configuration parameters.
Example:
After 4 "beeps" (** ** **) - jumper is switched and following digits are put in sequence: 000 90 10 033
Description:
(Delay before activation of the relay output (00s); Relay output activation time (9s); Maximum time for door to remain open (1s); Multiple programming of the Main and Installer code enabled; Sets OFF the FBK function (Keypad blocking function) and FBWP (relay output blocking function); User codes are 8 digits long; Master and Installer codes are 10 digits long)
Configuration parameters definitions:
[C1C2] : Delay before activation of the relay output (00..99s)
[C3C4] : Relay output activation time (00..99s)
[C5C6] : Maximum time for door to remain open (00..99s), (00 sets unlimited time)
[C7] : Multiple programming of the Main and Installer code enabled/disabled
[C8] : Sets on/off the FBK function (Keypad blocking function) and FBWP (Relay output blocking function)
[C9] : Sets the length of the users codes
[C10] : Sets the length of the Master and Installer codes
Default values of codes:
[Main code]: [1111(1)] , all digits are ?1?, the number of digits depends on the C10 parameter,
[Installer code]: [2222(2)], all digits are ?2?, the number of digits depends on the C10 parameter,
[User code 01]: [33(3)], all ?3?, the number of digits depends on C9 parameter,
[User code 02..55]: are blank, does not exist.
Codes programming:
[0][1][#][Code][#] Programs User 1 code.
[0][2][#][Code][#] Programs User 2 code.
....-...
[5][5][#][Code][#] Programs User 55 code.